Guide · Quality control

Particle Size and Emulsion Stability: How to Tell If the Batch Is Good

An emulsion that looks smooth in the kettle can still separate on the shelf in three weeks. Quality is three separate measurements — how small the droplets are, how narrow the distribution is, and whether the structure holds — and only one of them is visible to the eye. This page sets out what each measurement actually answers, which machine settings change the result and which leave it alone, and why an air bubble is regularly counted as a droplet by the instrument that is supposed to be measuring droplets.

Buffman BFM-G fixed vacuum homogenizing emulsifier: a polished stainless steel vessel mounted on a steel platform frame, with two blue-geared drive motors on the lid and the homogenizer assembly hanging below the vessel base, reached by a steel staircase on the right
One vessel, two drives. The two blue motors on the lid turn the slow stirrer; the assembly below the vessel base is the homogenizer, which turns at a speed roughly two orders of magnitude higher. Which of the two was running, and for how long, is what a batch record has to capture.

2007Manufacturing since
500+Staff
18,000 m²Gaoyou site
20+National patents

Quick answer

A batch is good when three things are true at once, and each needs its own measurement. First, the droplet size distribution is the one you asked for — quoted as D50 and span together, because a batch can hit its D50 target with a distribution twice as wide as the batch before it. Second, the emulsion survives an accelerated test that reproduces the failure mode you actually fear: creaming, coalescence or flocculation are three different mechanisms and no single test accelerates all three equally. Third, the batch record ties the result back to the settings that produced it — tip speed, the temperature at which the phases met, the cooling rate, the vacuum level and the point in the vessel the sample came from. Without the third, the other two cannot be repeated. And there is a fourth, less comfortable point: the machine sets the shear field, but the formulation sets the size that field can reach. A supplier who promises a number without your formula is guessing.

Why appearance carries almost no information

Two emulsions can look identical in the sample jar and behave completely differently in the tube. The eye is a poor instrument for this job, and it is worth being explicit about why.

An oil-in-water emulsion scatters light through the droplets in its continuous phase. Once the droplets are well below the wavelength of visible light the scattering becomes weak and the product turns from white towards translucent; above that, it is white and opaque regardless of whether the droplets are one micrometre or twenty. Gloss and opacity therefore tell you that some droplets are present in a certain size band. They do not tell you where the bulk of the volume sits, and they say nothing at all about the tail of large droplets that will decide whether the batch creams.

Viscosity is not a substitute either. A thickener added to a badly homogenised batch will hold the droplets apart by mechanical means for weeks, and the product will look acceptable for exactly as long as the yield stress holds. When it fails, it fails suddenly, and the failure looks like a formulation problem when it was a dispersion problem.

What each routine observation tells you, and what it leaves unanswered. The point of the table is that the top three rows are the ones a shift supervisor can do, and none of them can confirm a distribution.
Observation What it answers What it cannot answer
Colour and gloss Whether droplets exist in the size band that scatters visible light Where the volume median sits; whether there is a coarse tail
Viscosity at one shear rate Whether the structure is roughly as intended today Whether the structure will hold; whether droplets are being held apart by polymer rather than by the emulsifier
Smear on a glass slide Whether visible grit, streaks or phase separation are present Anything below a few micrometres; the difference between flocculation and coalescence
Droplet size distribution Where the volume sits, and how wide the spread is Whether the distribution is stable over time — it is a snapshot
Accelerated stability test Which failure mechanism is close to triggering The true shelf life; acceleration shifts mechanisms as well as speeding them up
Batch record Whether the result can be reproduced on the same machine next week Whether a different machine will reproduce it

The practical consequence is that a release specification built only on appearance and viscosity is a specification that passes bad batches. It is worth the cost of one particle size measurement on the development batches to find out where your process actually sits, because that number becomes the reference every later batch is judged against.

Reading a size distribution: D50 on its own will mislead you

Laser diffraction instruments report a volume-based distribution, and the numbers most often quoted from it are the percentiles. D10 is the diameter below which 10% of the volume sits, D50 the median, D90 the diameter below which 90% sits. Those three points describe the shape of the curve, and the shape is what your product experiences.

The single most useful derived figure is span, which normalises the width of the distribution by its own median:

span = (D90 − D10) ÷ D50

Span is dimensionless, so it can be compared between batches, between products and between suppliers without worrying about absolute size. A narrow span means most of the volume is in a tight band, which is what a well-controlled shear history produces. A wide span means some fraction was over-worked and another fraction escaped the shear zone entirely — and that second fraction is the one that will cream.

Two batches can report the same D50 and differ by a factor of two in span. If your specification says only “D50 = target”, both batches pass, and one of them will fail on the shelf. This is the most common way a particle size specification is written wrongly, and it is fixed by adding one number.

The figures to require on a particle size report, and what each one is for. If a report gives only one diameter, it is a marketing figure rather than a control figure.
Figure Definition What it is used for in production
D10 Diameter below which 10% of the volume lies Detects the fine fraction; a falling D10 with a stable D50 means the process is over-shearing part of the batch
D50 Volume median diameter The headline number, and the only one most specifications quote
D90 Diameter below which 90% of the volume lies Detects the coarse tail, which is what drives creaming and gritty feel
Span (D90 − D10) ÷ D50 Compares width between batches independently of absolute size
D[4,3] Volume-weighted mean diameter Heavily influenced by the coarse tail; useful as a companion to D50, not as a replacement
Measurement conditions Instrument, diluent, obscuration, pump speed Without these the number cannot be reproduced by anyone else, including your own second shift
Dilution can change the answer you measure

Laser diffraction needs the sample diluted into a circulating medium, and dilution changes the surfactant balance around the droplets. An emulsion measured in water alone can show a coarser distribution than the same emulsion measured in a diluent matched to its continuous phase, because droplets that were held apart in the product can come together in the measuring cell. The measured size is a property of the sample plus the method. This is why the method belongs on the specification sheet next to the number.

Which machine settings actually move the number

Not every knob on the control panel is a quality parameter. Some change the droplet size directly, some change the distribution only, some change the measurement rather than the product, and one of them — the stirrer speed — moves the batch around without creating any new surface at all.

Settings ranked by what they actually change. The distinction in the middle column is the one that saves the most time during troubleshooting: a change in the measured size is not always a change in the product.
Setting Effect on droplet size Why
Homogenizer tip speed Strong, and the primary lever Energy dissipation in the rotor-stator gap scales steeply with tip speed; it is the quantity that breaks droplets
Time at speed Strong up to a plateau Droplets break until the emulsifier can cover the new surface; past that point more time adds heat rather than fineness
Phase temperature at addition Strong, and often overlooked The size the droplets form at is set when the phases meet; the homogenizer can refine that size but cannot undo a bad start
Vacuum level Changes the measured size, not the true size Removes entrained air, which the instrument counts as droplets; see the next section
Cooling rate Little effect on size; large effect on stability Determines the crystal form of any fatty phase, and therefore whether the interfacial film stays intact
Stirrer speed alone None directly Bulk movement and heat transfer; at 0–63 r/min it cannot generate the shear that forms droplets

The two drives on a vacuum emulsifier are not two settings of one function. On our fixed BFM-G range the stirrer runs at 0–63 r/min and the homogenizer at up to 2,880 or 5,200 r/min on the 5–300 L models, and up to 2,880 or 4,500 r/min on the 500–2,000 L models. At the quoted maxima that is a ratio of 45.7 to 82.5 times between the two shafts depending on model and setting. A process sheet that says “mix 20 minutes” without naming which shaft was running at what speed is not a process sheet; it is a note that the batch was stirred.

Close view of a stainless steel vacuum emulsifier vessel head, showing two tall ribbed drive motors, a dial pressure gauge, a clamped sight-glass porthole and a manifold of valves with blue handles feeding into the domed lid
The vessel head is where the two speed regimes meet the batch. The gauge reads vessel pressure, the clamped porthole is the only view into the product without opening the lid, and the valve manifold is where a sample is drawn — which makes the sample point a process decision, not an administrative one.

Tip speed, not rpm, and what happens to it as the vessel grows

Rotational speed is quoted on every offer because it is easy to state. It is also the number that transfers least well between machines, because two rotors of different diameter turning at the same rpm produce different tip speeds, and tip speed is what the droplet experiences.

tip speed (m/s) = π × D × n ÷ 60, with D the rotor diameter in metres and n the shaft speed in r/min.

Worked with two diameters, the point becomes concrete: a 100 mm rotor at 5,200 r/min gives about 27.2 m/s at the rim, while a 200 mm rotor at 4,500 r/min gives about 47.1 m/s. The second machine reads slower on the tachometer and is about 1.7 times more aggressive at the gap. Comparing the two by rpm alone reverses the conclusion.

The second thing that changes with scale is installed power per litre, and it is worth calculating before you assume a lab result will transfer:

Homogenizer motor and maximum speed by capacity for the fixed BFM-G range, with installed power divided by working capacity. The last column is calculated from the two figures to its left; it is the number to think about when scaling a recipe up.
Working capacity Homogenizer motor Max homogenizer speed Installed power per litre
100 L 4 kW 5,200 r/min 40.0 W/L
200 L 5.5 kW 5,200 r/min 27.5 W/L
300 L 7.5 kW 5,200 r/min 25.0 W/L
500 L 11 kW 4,500 r/min 22.0 W/L
1,000 L 15 kW 4,500 r/min 15.0 W/L
2,000 L 18.5 kW 4,500 r/min 9.25 W/L

Read down the last column. From the 100 L unit at 40.0 W/L to the 2,000 L unit at 9.25 W/L, the installed homogenizer power per litre of product falls by a factor of 4.3. That is not a defect in the larger machine — it is geometry. Heat transfer area and shear zone both scale more slowly than volume, and a larger rotor compensates by reaching a comparable rim speed at lower rpm, which is exactly why the maximum falls from 5,200 to 4,500 r/min.

But it does mean that a development batch made on a small unit at 40 W/L and a production batch made on a 2,000 L unit at 9.25 W/L are not the same process, even at the same tip speed. Either the production batch needs longer in the gap, or it needs a second pass, or the target size has to be re-established on the production machine. Planning for that before the machine is ordered is cheaper than discovering it during commissioning.

The one number we will not quote without your formula

We do not publish a single achievable D50 for the emulsifier range, because the achievable size is a property of the formulation as much as of the machine. Surfactant system, phase ratio, viscosity of both phases and the presence of solids all shift the result. What we will do is supply the rotor diameter, the gap setting and the speed range for a specific configuration, so that you can calculate tip speed and compare our machine with another on equal terms. Comparing a machine that is specified only in rpm and kW against one specified in tip speed is a comparison between two different kinds of information.

Air is counted as a droplet, which is why vacuum level affects the measurement

Laser diffraction measures the angular scatter of light, and it cannot tell a droplet from a bubble. A spherical void with a refractive index of 1.0 scatters light into the same detector array as a droplet of a different refractive index, and the instrument will assign it a size. So a sample drawn from a batch that is still aerated reads coarser than the same emulsion reads after deaeration — and the D90 is where the difference shows, because entrained bubbles are large relative to the droplets.

This produces a specific and confusing pattern in a plant: the batch measures badly on the day it is made, then measures well after standing overnight, and the assumption is that the emulsion “settled in”. What usually happened is that the air left. The product did not improve; the sample did.

Running the vessel under vacuum addresses it at source. Air entrained during loading and during the dispersion of powders is drawn out while the batch is under vacuum, which is the reason the emulsifier is built as a vacuum machine rather than an open one. The catalogue vacuum differs by capacity, and the difference is a consequence of scale:

Ultimate vacuum by machine and capacity, converted to absolute pressure, with the boiling point of water at that pressure from the Antoine equation. The boiling points are physical consequences of the quoted vacuum rather than test results; in practice the product has to be held somewhat above them for deaeration to proceed.
Machine / capacity Ultimate vacuum (gauge) Absolute pressure Water boils at What it means for a sample
Toothpaste machine, all capacities −0.097 MPa 4.3 kPa 30.4 °C Paste is heavily aerated by its own mixing action; the deepest vacuum in the range is specified here because of it
Emulsifier, 100–200 L −0.090 MPa 11.3 kPa 48.3 °C Small headspace, so the deepest emulsifier vacuum is reachable here
Emulsifier, 300 L −0.085 MPa 16.3 kPa 55.8 °C Intermediate case
Emulsifier, 500–2,000 L −0.080 MPa 21.3 kPa 61.5 °C Large headspace volume; the shallower figure is scale, not a weaker pump

Two practical readings follow. First, a vacuum figure quoted on a specification is what the pump can hold against a sealed vessel — it is not what you will achieve while the product is releasing solvent or steam. If your formula contains a volatile component, say so before the condenser and pump are sized, because neither can be added economically afterwards. Second, the capacity you choose sets the temperature at which deaeration becomes effective: roughly 48 °C on a 100 L unit against roughly 62 °C on a 2,000 L one. If the formula cannot take 62 °C, the answer is not a better pump; it is a smaller vessel or a split batch.

Hydraulic lifting vacuum homogenizing emulsifier with the lid raised above an open stainless steel vessel, showing the frame agitator with wall scrapers hanging from the lid, the homogenizer below the vessel base, a control cabinet with a touchscreen on the left and a steel staircase on the right
Lid raised on a hydraulic lifting unit. The frame agitator and its wall scrapers hang clear of the vessel, which is the only position in which the scraper contact against the wall can be checked — and a scraper that has stopped touching the wall shows up as a cold band, a slow cooling rate, and a batch that varies from run to run.

Temperature: where the droplets are born, and how fast you leave

Two temperature decisions matter more than the rest, and neither is a homogenizer setting.

The temperature at which the phases meet. Droplet size is largely set at the moment of emulsification, when the dispersed phase is added into the continuous phase under shear. Add too cool and the dispersed phase is viscous, so it resists breakup and the distribution starts coarse. Add too hot and you risk the opposite problem: the interfacial film forms fast but the droplets are so mobile that coalescence competes with breakup, and the emulsifier has to work harder to hold a size it could have started at. For a formulation containing a fatty phase with a melting point, the addition temperature also determines whether that phase is liquid or crystalline when it is broken up, which changes the result more than the speed setting does.

How fast you cool afterwards. Cooling is when a fatty phase crystallises, and the crystal form decides whether the interfacial film survives. Cool too slowly and crystals grow large and can pierce the film; cool too fast and the wall layer sets before the bulk does, which is why a wall-scraping agitator is fitted — it keeps the heat transfer surface renewed and stops over-thickened material building up on the cooled wall instead of being mixed back into the batch.

The heating method sets how quickly you can move between these setpoints, and the installed power differs sharply between the two options:

Heating power by capacity for the fixed BFM-G range, electric against steam. These are catalogue installed loads, not running consumption; the ratio column is calculated from the two figures to its left.
Working capacity Steam heating power Electric heating power Electric ÷ steam
100 L 10 kW 64 kW 6.4×
200 L 14.75 kW 76.75 kW 5.2×
300 L 19 kW 97 kW 5.1×
500 L 26.7 kW 110.7 kW 4.1×
1,000 L 38.5 kW 146.5 kW 3.8×
2,000 L 48.5 kW 204.5 kW 4.2×

The electric option carries a much larger installed load, from 6.4 times the steam figure at 100 L to about 4.2 times at 2,000 L, and that load is what sets the achievable ramp rate. Whether you want a fast ramp is a formulation question: fast is an advantage when a heat-sensitive active has to spend as little time as possible at temperature, and a disadvantage when a slow controlled cool is what the crystal structure needs. Neither option is inherently better; the point is that the heating method is a process decision and should be settled with the phase temperatures, not with the utility available on site.

Stability tests: choose the one that reproduces your failure mode

An accelerated stability test is a prediction, not a proof, and the prediction is only as good as the mechanism it accelerates. Creaming, coalescence and flocculation fail differently, and a test that stresses one of them can leave the others untouched.

Four tests and what each is good for. The right column is the reason a single accelerated result cannot be presented as a shelf life.
Test What it accelerates What it can show falsely
Centrifugation Density-driven separation, so creaming and sedimentation A clean result when the real risk is coalescence, because the centrifugal field separates droplets without forcing them to merge
Elevated-temperature storage Chemical and interfacial degradation, and the mobility that drives coalescence Failure caused by the test itself — an emulsifier that hydrolyses or a fatty phase that melts at the test temperature is not showing you a shelf problem
Freeze–thaw cycling Mechanical damage from ice crystal growth and from the volume change Irrelevance for a product that will never be frozen, which is most cosmetic emulsions shipped and stored warm
Ambient storage with periodic measurement The real mechanism, slowly Nothing, except that it takes months and cannot gate a launch on its own
Microscopy, including polarised light Flocculation versus coalescence, and crystal presence in the continuous phase A quantitative size — microscopy counts what it looks at, which is a small and possibly unrepresentative field
Conductivity of the neat sample Which phase is continuous; a change indicates inversion The degree of dispersion. A conductive sample confirms oil-in-water, not that the droplets are small

The most useful routine is a combination: a size distribution at release, microscopy on the same sample to confirm what the instrument saw, and one accelerated test chosen for the failure you have actually experienced. If your last three complaints were separation in warm markets, centrifuge plus elevated-temperature storage is the pair that matters. If they were grit or a change in feel, you have a coalescence problem and neither of those will find it.

Keep a retention sample of every batch, and measure it later

The cheapest stability data you will ever have is the sample you kept and did not open. When a complaint arrives six months after shipment, a retained sample measured alongside the returned product separates “the batch was made wrong” from “the batch degraded” in one afternoon. Without it, both explanations remain open and the investigation becomes an argument.

Where you take the sample changes the answer

A vessel is not a well-mixed volume at the moment you open the valve. Material near the wall is cooler than material in the centre, material at the top has had less exposure to the homogenizer than material that has just passed through it, and what leaves a bottom outlet at the start of a draw is not the same as the bulk.

Three habits remove most of the ambiguity. Draw the sample after a defined period of circulation at a defined stirrer speed rather than whenever the operator is free. Draw it from the same point every time, and record which point. And discard the initial portion that leaves the valve, because it has been sitting in the dead volume of the outlet since the last batch.

The geometry matters as well. A homogenizer at the base of the vessel draws material from the bottom and throws it outward and up the wall, which closes a circulation loop that returns the upper layer to the shear zone; that is the reason our emulsifier range is built with the head at the base. But a loop that closes through the whole batch also means the sample point is a choice about when in the loop you are sampling. That trade-off, and the cases where a base-mounted head is the wrong answer, is set out on the page comparing bottom-entry and top-entry homogenizers.

Vacuum emulsifying production unit with two stainless steel vessels on a raised steel platform, a white control cabinet with coloured indicator lamps and switches, blue-cased valves beneath the right-hand vessel, and a steel staircase up to the platform
Two vessels sharing one platform, with the control cabinet between them. On an arrangement like this the sample valve, the sight glass and the instrument panel are three different places, and the process sheet has to name which one the release sample comes from.

A batch record that can actually be compared

If two batches differ and the record has four fields, you will not find out why. The following six items are the minimum that makes a batch reproducible on the same machine, and they cost nothing to record.

  1. Which shaft ran, at what speed, for how longStirrer and homogenizer separately. “Mixed 20 minutes” is not a record; the two shafts differ by 45.7 to 82.5 times in speed and do entirely different jobs.
  2. Phase temperature at addition, and the temperature at the end of homogenisationSize is largely set when the phases meet. Without this figure, a change in size cannot be explained by anything else in the record.
  3. Vacuum reached, and whether the product was under vacuum at the time of samplingA sample drawn from an aerated batch reads coarser than the same product measured after deaeration, and that difference will be mistaken for a process change.
  4. Cooling profile, and whether the scrapers were runningCrystal form and wall-layer build-up both hinge on this, and both show up later as a stability result rather than an immediate defect.
  5. Sample point and sample timeThe valve, the top, the sight glass — name it, and say how long after the homogenizer stopped the sample was taken.
  6. Result with the method attachedD10, D50, D90 and span, plus the instrument and the diluent. A size without a method cannot be compared with anything, including your own earlier batches.

None of these require new equipment. They require the process sheet to have six more lines than it has now, and the discipline to fill them in on the shift where everything went wrong — which is the shift where the record is most valuable and least likely to be completed carefully.

If you are at the stage of specifying a machine rather than debugging a batch, the machine-side questions are collected on the vacuum homogenizing emulsifier guide, and the comparison between the three body styles is on the series selection page. Where the money goes between the options is set out separately in what drives the cost of a vacuum emulsifier.

Questions we are asked about particle size and stability

What droplet size should a cosmetic emulsion have?

There is no universal target, and any supplier who quotes one for your product without seeing the formula is guessing. What matters is that the distribution is narrow and that it is stable, and both are properties of your formulation under your process. The useful approach is to make three development batches, measure D10, D50, D90 and span on each, and pick the process setting that gives the narrowest span at a size your stability test passes. That number then becomes your own reference, and it is worth more than any figure quoted from outside.

Why does my batch measure better the day after it is made?

Almost always because the air left it. Laser diffraction cannot distinguish a bubble from a droplet and assigns both a size, so entrained air inflates the coarse end of the distribution — most visibly at D90. A batch that measures badly on the day and well the next morning did not improve; the sample degassed. The fix is at the machine: deaerate under vacuum before sampling, and record the vacuum reached with the result. If the batch is properly deaerated at the vessel and still reads coarse, then you have a genuine dispersion problem.

Is a lower D50 always better?

No, and chasing it can damage the product. Smaller droplets mean more interfacial area, which needs more emulsifier to cover it; past the point where the emulsifier is exhausted, further shearing produces droplets that coalesce almost as fast as they form, and the measured distribution tends to widen rather than shift. There is also a cost in heat and time, and in a formulation containing a shear-sensitive polymer or a crystalline active, in the material itself. The target is a narrow distribution at the size your stability test accepts, not the smallest number the machine can produce.

Why does the same recipe give a different result on a bigger machine?

Because installed homogenizer power per litre falls as the vessel grows. On our fixed range the homogenizer motor rises from 4 kW at 100 L to 18.5 kW at 2,000 L, but the product volume rises twentyfold, so installed power per litre drops from 40.0 W/L to 9.25 W/L — a factor of 4.3. A larger rotor partly compensates by reaching a similar rim speed at lower rpm, which is why the maximum speed falls from 5,200 to 4,500 r/min, but the process is not identical. Expect to re-establish the target on the production machine rather than assuming the lab setting transfers.

How long should a stability test run before we release a batch?

Release should rest on a measurement you can repeat today — a size distribution with the method recorded, plus a visual and viscosity check against your own baseline — and not on an accelerated stability result, which predicts rather than proves. Use the accelerated test to qualify the formula and the process, and use retention samples to answer later complaints. We do not quote a shelf life for a product made on our machine, because the shelf life belongs to the formulation; what the machine contributes is a consistent shear history, which is what makes the stability result repeatable at all.

What should we send you when the batch result is wrong?

The recipe with phase ratios, the size report with its method, the batch record covering both shaft speeds and times, the phase addition temperature, the vacuum reached, and where the sample was taken. With those we can usually separate a machine problem from a formulation problem in one exchange. Sending only the D50 figure and asking what is wrong with the machine tends to produce advice about the machine, which is often not where the problem is. Our manufacturers directory page explains what documentation we will and will not provide before an order.

Send the batch that failed, with the numbers, and we will tell you where to look

The recipe, the size report with its method, and the record of what the machine did. With those three we can say whether the shear history is the cause, the phase temperature is the cause, or the problem sits in the formulation and no machine setting will fix it — and we will say so plainly rather than proposing a larger homogenizer.